REACT - Repositionable Elastic Adaptive Customisable Traction device for endoscopic procedures

REACT System - Advanced Traction for Endoscopic Submucosal Dissection

Repositionable Elastic Adaptive Customisable Traction

A revolutionary multipoint traction system for endoscopic submucosal dissection (ESD) that enhances procedural safety and efficacy through customizable elastic bands.

Key Features of REACT Traction System for ESD

Repositionable

Easily adjust traction points during the procedure without interrupting workflow

Adaptive

Automatically adjusts tension based on tissue resistance and procedural needs

Customizable

Multiple band configurations to suit different anatomical locations and lesion types

Clinical Study Results: REACT System Safety and Efficacy

Ghent University Hospital Study (2023-2025)

Study Design

  • - 40 colorectal lesions (20mm or larger)
  • - 22-month observation period
  • - Tertiary referral center
  • - Median lesion size: 30mm

Key Outcomes

  • - 90% R0 resection rate
  • - 95% improved submucosal access
  • - 17.6 mm2/min median dissection speed
  • - 97.5% en-bloc resection rate

Safety Profile

  • All perforations managed conservatively
  • No surgical interventions required
  • No delayed perforations observed
  • Comparable to established traction methods

Procedural Benefits

  • 5.5 minute median deployment time
  • Real-time adjustability during procedure
  • 97.5% en-bloc resection rate
  • Low device failure rate (1.3% clip detachment)

REACT System Technical Specifications & Materials

Materials

Elastic Bands

Medical-grade latex (Fox 1/4 inch 3.5Oz, Ormco)

Attachment Method

Re-openable rotatable clips (ScopeClip, Creo Medical)

Connection System

Cow hitch knots for secure band linkage

Configuration Options

REACT-3

3 traction bands - small lesions (47.5% usage)

REACT-4

4 traction bands - medium lesions (32.5% usage)

REACT-5 & REACT-6

5-6 traction bands - large/complex lesions

Color-Coding System

Purple

Fixation Band

Green

Linking Band

Pink

Traction Bands

Orange

Traction Bands

REACT System Video: Colorectal ESD Procedure Demonstration

Watch the REACT-6 system being deployed during a colorectal ESD procedure

Procedural Applications & Techniques

Deployment Protocol

  1. 1

    Lesion Preparation

    Circumferential incision with partial trimming for mucosal flap mobility

  2. 2

    REACT Introduction

    Grasp traction band with re-openable clip, pull into endoscope cap

  3. 3

    Sequential Attachment

    Attach traction bands evenly around lesion margin, perpendicular to edge

  4. 4

    Fixation

    Attach fixation band to opposite colonic wall above lesion midpoint

Dynamic Adjustment

Real-time repositioning of bands and modification of traction direction as needed

Anatomical Coverage

52.5% rectal, 22.5% sigmoid, 15% transverse colon lesions successfully treated

Rapid Deployment

Median deployment time of 5 minutes 33 seconds with minimal training required

Advantages Over Traditional Methods

FeatureREACTATRACTClip-with-LineS-O Clip
Traction PointsMultiple (3-6)MultipleSingleSingle
AdjustabilityReal-time repositioningAdaptive tensionLimitedFixed
Material CostLow (~$5)HighLowHigh
Special EquipmentNone requiredProprietary deviceNoneProprietary device
Assembly Time< 2 minutesPre-assembledVariablePre-assembled
Reported Speed17.6 mm²/min37.4 mm²/minNot specifiedNot specified

REACT System Research Publications & Clinical Trials

Now PublishedGastrointestinal Endoscopy

Published Clinical Study

REACT Multipoint Elastic Traction for Colorectal ESD: A Retrospective Single-Center Feasibility Series of 59 Consecutive Cases


Gastrointestinal Endoscopy, • DOI: 10.1016/j.gie.2025.12.273

Abstract

Background and Aims: Effective traction for endoscopic submucosal dissection (ESD) should be applicable to diverse lesion morphologies and locations, adapting as dissection progresses, allow repositioning and be cost-effective. To meet these criteria we developed Repositionable Elastic Adaptive Customizable Traction (REACT), a customizable, low-cost multipoint traction method assembled from orthodontic elastic bands. This study aimed to evaluate the safety and feasibility of REACT-assisted ESD in a retrospective colorectal series.

Read Full ArticleClinical Trial NCT06467929

Study Authors

  • • Poortmans PJ - University Hospital Ghent
  • • Montori M - Università Politecnica delle Marche
  • • Debels LK - University Hospital Ghent
  • • Argenziano ME, Botelberge T, Hoorens A
  • • Smeets S, Sorge A, Tornai T, Desomer L
  • • Tate DJ - University Hospital Ghent

Study Details

  • Design: Retrospective single-center series
  • Cases: 59 consecutive colorectal ESDs
  • Center: University Hospital Ghent, Belgium
  • Journal: Gastrointestinal Endoscopy (Elsevier)

Contact Us: REACT System Training and Implementation

Join leading endoscopy centers worldwide in adopting this innovative traction system

Department of Gastroenterology and Hepatology

University Hospital Ghent - C. Heymanslaan 10 -B-9000 Gent,Belgium

[email protected]